ALLWEILER screw pump It is a kind of pump widely used in the industrial field. Due to long-term use or change of medium properties, it may lead to blockage or dirt accumulation inside the pump body. In order to ensure the normal operation of the pump and extend its service life, it is necessary to wash and clean the pump regularly. The following is for ALL WEILER Screw pump Detailed operation steps for flushing and cleaning:
Step 1: Stop the operation of the pump. Before any flushing and cleaning operation, stop the operation of ALLWEILER screw pump first. Use the corresponding switch to cut off the power supply to ensure that the pump stops completely to avoid accidental injury.
Step 2: Empty the pump body to avoid accidents during cleaning and maintenance, COLFAX agent It is necessary to empty the medium in the pump body. Open the discharge valve to discharge all the fluid or medium in the pump body. Ensure that the discharge valve is opened at a proper angle to avoid pollution or injury caused by the ejected medium.
Step 3: Disassemble the pump connector ALLWEILER screw pump is usually composed of multiple connectors, such as flanges, pipes, valves, etc. According to the actual situation, remove these connecting pieces and separate them from the pump body. Pay attention to handle with care during this process to avoid damaging or bending the connector and affecting subsequent use.
Step 4: Clean the inside of the pump body, select the appropriate cleaning solution or solvent according to the needs, and apply it evenly on the inside surface of the pump body with a brush or cloth. Focus on cleaning the inner wall of the pump body and the impeller to remove the attached dirt or sediment. It can be wiped and washed repeatedly as required to ensure that the dirt is completely removed. CIRCOR SECCO
Step 5: Flush the inside of the pump body After cleaning the inside of the pump body, use appropriate flushing fluid or clean water for flushing. Inject the flushing fluid into the pump body, and make the flushing fluid flow through the inside of the pump body by opening the discharge valve or the injection port to clean the residual dirt or detergent. It can be flushed repeatedly as required to ensure that the inside of the pump body is completely clean.
Step 6: Clean the connector When cleaning and flushing the inside of the pump body, attention should also be paid to cleaning and flushing the connector. Use the same cleaning solution or solvent to clean the surface of the connector to remove the attached dirt. It can be wiped with a brush or cloth to ensure that the surface of the connector is clean and free of dirt.
Step 7: Install the connector After cleaning and flushing the pump body and the connector, reinstall the connector. According to the original connection method, connect the connector with the pump body and fasten it with the corresponding tools. Ensure that the connector is closely connected with the pump body to avoid water leakage or leakage.
Step 8: Check the pump body and connectors. After the flushing and cleaning operations are completed, carefully check the pump body and connectors. Check whether there is any residual dirt or cleaning fluid inside the pump body, and further cleaning if necessary. At the same time, check whether the connectors are installed correctly and fastened reliably, and eliminate any problems or potential leakage risks. Viking
The above is the operation steps for flushing and cleaning the ALLWEILER screw pump. Please read and understand the relevant safety tips and operation manuals before any flushing and cleaning operation. Ensure that operators have sufficient operating experience and skills to ensure the safety and effectiveness of operation.