Please be sure to operate in strict accordance with the following requirements, or it will cause you personal and property losses. Safety precautions for horizontal screw centrifuge
1 (Without the prior written approval of Alfa Laval, the horizontal spiral centrifuge shall not be used to separate flammable, toxic, and
Corrosive and radioactive substances.
2 (Before preparing to install or operate the horizontal screw centrifuge, please read this safety manual and operation manual in detail, and
And comply with all requirements therein.
3 (Do not operate the centrifuge with damaged warning signs or without warning signs.
4 (If the vibration amplitude of the machine exceeds 24 mm/s (American standard: 1 inch/s), please stop the machine immediately~5 (when the feed temperature exceeds the limit specified in the data list of the installation, operation and maintenance manual, it is not allowed to use
7 (Do not exceed the maximum rotating speed and fixed speed of the drum specified in the manual data list or marked on the centrifuge nameplate
Run the centrifuge at maximum density.
8 (Do not operate the centrifuge without belt shield and other protection facilities. 9 (Regularly check all automatic cut-off devices and monitoring systems to ensure their normal operation. 1.0-1
Alfa Laval Operation Manual
10. Failure to determine whether the centrifuge is completely stopped, whether the main power supply is completely disconnected, and whether the main switch is disconnected and locked safely
Please do not attempt to disassemble the centrifuge when it is fixed.
11. When cracks, dents, holes or grooves appear on the centrifuge drum, motor or support frame, do not operate the centrifuge
Mind machine.
12. Do not use tools not recommended by Alfa Laval to disassemble or install the centrifuge. 13. This centrifuge cannot be used beyond the scope of application or raw material processing signed with Alfa Laval when purchasing equipment.
14. Follow all lubrication procedures and procedures for the equipment.
15. Check the base of centrifuge and motor as well as all supporting frames, casings and connecting pipe fittings at least once a year.
16. Do not place rags or loose clothing near rotating parts.
17. Please strictly follow the steps required by Alfa Laval when disassembling, installing or operating, operating and maintaining the machine.
Please do not change the operation steps without Alfa Laval's consent.
Extended reading: Alfa Laval, Alfa Laval rotor pump, AlfaLaval centrifuge