      VIKING gear pump It is a kind of pump commonly used for conveying various liquids. It has the characteristics of simple structure, reliable use and convenient maintenance. To ensure that Gear pump The normal operation and extended service life, correct repair and maintenance are essential. The repair and maintenance methods of VIKING gear pump will be introduced in detail below.

1、 Gear pump maintenance

  1. Repair of leakage: if leakage is found, first check whether the sealing gasket is intact and adjust the fastening screw properly. If necessary, replace the sealing gasket or O-ring. The connection with poor sealing can be repaired with appropriate thread sealant. COLFAX agent

  2. Maintenance of variable shaft seal: regularly check the wear of variable shaft seal. If there is obvious wear or leakage, it is necessary to replace it with a new one. When replacing the shaft seal of the transformer, the relevant operating instructions should be followed to ensure the correct installation and proper lubrication measures should be taken.

  3. Maintenance of gear box: the gear box of the gear pump is an important moving part, so it is necessary to regularly check whether the lubricating oil of the gear box is sufficient, and replace it according to the use condition. Other problems of the gearbox, such as gear wear and bearing problems, should be repaired or replaced in time. CIRCOR SECCO

  4. Motor maintenance: regularly check the operation of the motor to ensure that the current and voltage output by the motor are stable. If the motor has abnormal sound or heat, it shall be handled in time. If the motor needs to be replaced, select the appropriate model and power, and install it correctly according to the instructions.

  5. Maintenance of other parts: for other parts, such as seal rings, bearings, etc., regular inspection and maintenance are also required. If any problem is found, replace or repair it in time. Viking

2、 Gear pump maintenance

  1. Cleaning the gear pump: after using the gear pump for a period of time, some dirt may accumulate, which may cause the internal blockage of the pump or reduce the pump efficiency. Therefore, it is necessary to clean the gear pump regularly. During the cleaning process, make sure to use proper cleaning agent and thoroughly clean each part.

  2. Lubrication of gear pump: the lubrication of gear pump is the key to ensure its normal operation. First, check the lubricating oil level of the gearbox regularly to keep it within the correct range. At the same time, the lubricating oil shall be replaced according to the service conditions and lubricant requirements. In addition, the lubrication system shall be inspected and maintained regularly to ensure that the lubricating oil can reach each bearing and gear effectively.

  3. Daily maintenance: the gear pump needs regular daily maintenance. It includes cleaning the filter, checking whether the pipeline connection is tight, and checking whether the pump body and other parts are abnormal. The problems found shall be handled and repaired in time. VIKING gear pump

  4. Regular inspection: it is very important to conduct a thorough inspection of the gear pump regularly. Through inspection, potential problems can be found in time and corresponding measures can be taken. The inspection includes whether the screws are fastened in place, whether the bearings have abnormal sound and wear, and whether the seals are in good condition.

Conclusion: The above is a detailed explanation of the repair and maintenance methods of VIKING gear pump. Through correct repair and maintenance, the normal operation and service life of the gear pump can be ensured. It is recommended that the repair and maintenance should be carried out in strict accordance with the operating instructions to avoid operating errors. In addition, the pump shall be checked regularly to find and solve problems in time.