//data.zz.baidu.com/urls?site=www.whjygj.cn&token=vCR0fAjiWe30M6Ky

上海高端私人预约

 News

News Center

Current location: home page > News Center > Technical Information

Parameter table of gear pump R4.5/35 to R6.0/160 UNI

2022-12-20 11:51:02
second

1 Overview

The technical descriptions in this catalog are used as general information. During assembly, operation and maintenance, attention must be paid to the operating instructions and the provisions indicated on the product. We reserve the right to modify the technical parameters, model selection and ordering parameters, accessories and availability. All dimensions are in millimeters.

2 Application field

RICKEIER Gear pump It is used in hydraulic and lubricating systems, as well as devices for conveying various oils or lubricants..

 Gear pump

 Gear pump

3 Description

3.1 Structure

Figure 2: UNI pump 1 housing with pipe interface 2 wheel housing 3 drive wheel shaft 4 inner gear ring

3.2 Product description

The RICKMEIER UNI pump always pumps media in one flow direction. This feature makes UNI pumps suitable for all applications where reverse flow is not allowed. If the drive shaft rotates in the opposite direction, the pump will automatically switch while maintaining a single flow direction. Compared with other solutions, this ingenious design and the use of the least number of parts make it more advantageous. A major feature of RICKMEIER UNI pump is that its structure is very compact, so it can be installed in a narrow space (such as wind turbine room, marine gearbox or gas generator). Compared with other solutions, RICKMEIER UNI pump has small flow resistance even under the condition of high viscosity, that is, small internal pressure loss. RICKMEIER UNI pump has no wearing parts such as seals and valves, so the maintenance cost is very low. Even if it runs for a long time, it does not need maintenance.

4 Operating principle

 Gear pump

Figure 3: Transmission principle of internal gear pump

UNI pump is an internal spraying gear pump, so it is a rotary displacement pump. When the drive gear shaft and the inner gear ring rotate, the medium accumulated in the clearance between the teeth will be transported from the suction side to the pressure side, where it will be pressed out to the pressure side through the mutual spraying gears. The suction side and pressure side are sealed by a sealing plate. The transmission of flowing medium causes pressure drop on the suction side of the gear pump. Due to the continuous engagement of the teeth, the flow medium compensates the pressure peak by constantly flowing in, thus forming a continuous conveying process. This process is performed in the same way for both gaseous and liquid media. Therefore, the gear pump can exhaust gas at the suction side by itself until the whole pipe is filled with liquid transmission medium.


1 Limitations of use The following describes the maximum operating conditions allowed for UNI pumps of standard specifications. If you need to exceed or fall below these numerical ranges, please contact RICKMEIER. As a precondition to ensure long service life and maximum operation reliability, the transmission medium shall be lubricated, as clean as possible and non corrosive, but in any case, there shall be no hard mixture. In addition, the following scope also applies:

 Gear pump

1) According to the application and operating conditions, the viscosity can be lower or higher, please contact us. 2) Undissolved gases in the transport medium may cause increased noise. 3) Pressure gauge 4) can also be lower in a short time (for example, in the startup state), please contact us.

 Gear pump

1) Speed=1450 rpm, viscosity=33 mm ²/ s. Working pressure=5 bar 2) Avoid high working pressure at low rpm. In the rated operating mode, it must be ensured that the pressure on the pump outlet side is at least 1 bar (pressure gauge). If you want to determine the minimum allowable speed for your application, please contact us. 3) The sound pressure level values given are applicable to the cavitation free operation of UNI pump on the test bench (distance from the pump: 1 m).