VIKING gear pump It is a kind of pump equipment widely used in the industrial field, and its importance is self-evident. To ensure that Gear pump To achieve the best performance, we need to install and debug correctly. This article will introduce the installation and commissioning steps of VIKING gear pump in detail, and give some suggestions to help readers improve the efficiency of installation and commissioning. Viking
1、 Preparation:
Confirm the model and specification of the pump and check whether they are consistent with the actual requirements.
Prepare supporting installation tools and equipment, such as wrench, oil dipstick, pressure gauge, etc.
Determine the installation position of the gear pump according to the actual situation.
It should be noted that before installing the gear pump, you should carefully read the product manual to understand the characteristics, performance indicators and installation requirements of the product.
2、 Installation steps:
Check the running direction of the pump, and determine whether to change the direction of the pump according to the actual needs.
Clean the installation position to ensure that it is flat, clean and able to bear the weight of the pump.
Place the pump at the installation position, and use a level gauge to adjust the levelness of the pump to ensure its smooth installation.
Use spanner and other tools to firmly tighten all connection parts of the pump, especially the connection between inlet and outlet pipes. ASL electrostatic oil filter
Check whether the fastening bolts of the pump are loose. If they are loose, tighten them immediately.
Connect the inlet and outlet pipes, and pay attention to the tightness and firmness of the pipe connection.
After the pump is installed, a filling test run shall be carried out to remove the air from the pipeline and interface, and the sealing performance of the pump shall be checked.
3、 Commissioning steps:
First, check whether the speed of the pump meets the design requirements, and use a tachometer for measurement.
Check whether the suction pressure and discharge pressure of the pump are within the normal range, and adjust them as required.
Check whether the oil level of the pump is within the normal range. If lubricating oil needs to be added, it should be added according to the requirements in the product manual.
Start the pump and observe the operation of the pump, including whether the rotation is stable and whether the shaft temperature is too high.
When the pump is working normally, gradually increase the load, and observe the performance and operating state of the pump.
Regularly check the operation of the pump, pay attention to whether the sound and vibration of the pump are normal, and timely find and eliminate abnormal conditions.
If any problem is found during commissioning, stop the machine for inspection in time, find out the cause of the problem and handle it accordingly. IDEX
4、 Precautions:
The installation and commissioning shall be carried out in strict accordance with the requirements in the product manual and shall not be changed at will.
During installation and commissioning, pay attention to the safety of staff to avoid accidents.
When the pump is at a standstill, it is not suitable to stay in a high-pressure or high-temperature environment for a long time to avoid affecting the sealing performance of the pump.
The operating environment of the pump shall be kept dry and clean to avoid foreign matters affecting the normal operation of the pump.
Check and maintain the gear pump regularly, including cleaning the pump surface and checking the wear of seals.
Conclusion: Correct installation and commissioning is an important link to ensure the best performance of VIKING gear pump. Only reasonable installation and commissioning can ensure the normal operation of the pump and extend its service life. Therefore, in the process of installation and commissioning, we need to carefully follow the requirements in the product manual, strictly grasp the installation and commissioning steps, and observe the precautions to ensure safety and the best performance of the pump.