VIKING gear pump It is a commonly used industrial pump, which is used to transport various liquid media. Correct installation Gear pump It is critical for its normal operation and performance. The following details how to install the VIKING gear pump and the precautions.
Preparation before installation:
Before installation, carefully read the installation instructions of the gear pump to understand the installation requirements and steps.
Prepare the tools and equipment required for installation, and ensure that all installation parts are complete.
Check whether the gear pump is damaged or deformed. If there is any problem, replace or repair it in time.
Selection of installation location:
Select a flat, dry and well ventilated location to install the gear pump to ensure the stability and normal operation of the pump.
It is close to the liquid storage tank and pipeline, which is convenient to connect the transmission pipeline. ASL electrostatic oil filter
Install the gear pump:
Place the gear pump vertically on the installation position to ensure that the base is in flat contact with the ground.
Adjust the base bolt to fix the pump on the ground and keep it horizontal. IDEX
Connect the input and output pipes through flanges or threaded joints, and pay attention to whether the direction and position of the connection are correct.
Connect the motor and gear pump to ensure normal operation. Pay attention to whether the motor rotates correctly.
Install the electrical system:
Connect the power line and ground wire to ensure the correct wiring of the electrical system and avoid short circuit and electrical hazards.
Check whether the protective measures of the electrical system are complete, such as overload protection, leakage protection, etc.
Start debugging:
After all components are installed, start the commissioning, check whether the gear pump operates normally, pay attention to the sound and observe the operation.
Adjust the flow and pressure of the conveying medium to ensure the normal operation of the pump under the design condition.
In general, the installation of VIKING gear pump needs to be careful to ensure that every step is correct. At the same time, regular maintenance and inspection shall be carried out to ensure the long-term stable operation of the gear pump. I hope the above contents can be helpful when you install the VIKING gear pump. IMO agent