COLFAX Power Generation and Industrial Solutions

2022-10-10 20:35:09
second

Peristaltic pump for mobile filtered water Eversburg sewage treatment plant aims to

With a population of million, it is one of the three factories operated in the city of Osnabluk in northern Germany. However, in 2005, its actual load was close to 309000 population (COD 80 mg/L), which made the nitrogen input level exceed the capacity of the plant.

In order to deal with this situation, engineer Peter Sikora organized a team to develop an alternative process based method for biological nitrogen removal. Their proposal was evaluated within the scope of the factory's idea management plan, called "my idea". The core of the proposal involves the use of existing basins and established biotechnology projects.

The decision to support the solution was accompanied by a step-by-step implementation plan: the feasibility study of the laboratory led to a pilot project

Factory. The positive results in this area were extended to small basin operation experiments. These findings lay the foundation for the implementation of a major system serving 60000 residents.

A critical aspect of this concept is the harsh pumping task of delivering filtered water to the nitrogen removal unit. The pH of water ranges from 11 to 11.5 and the temperature is about 30

° C, regulated by lime and iron III.

The factory initially used centrifugal pump, but its mechanical seal calcified, the pump leaked, and corrosive lime water penetrated into the motor. Therefore, these pumps can only be used for a few weeks at a time.

In 2006, the factory began to use Allweiler peristaltic pump to replace the centrifugal pump of another manufacturer. "Since then, the pump has been running around the clock without any problems," Mr. Sikora said. The hose material is very durable, and lime or any other component of filtered water will not cause any significant wear. In addition to the mechanical and chemical loads, the filtrate also releases ammonia. Therefore, the pump must not only be able to handle the critical liquid phase,

It must also be able to handle difficult gas phases.

Allweiler engineers provide detailed consulting services and work closely with the factory team to optimize the process so that pulsation and calcification will not affect the operation.