What preparations should be made before the use of ALLWEILER screw pump?

2023-09-06 15:54:52
second

Using ALLWEILER screw pump The following preparations are required before:

Confirm Screw pump Operating conditions of: in use ALL Before WEILER screw pump, it is necessary to confirm the working conditions of the pump, including the flow range, lift requirements, pressure rating, medium properties and temperature range of the pump. Select the appropriate screw pump model according to the nature of the medium and process conditions.

Check the appearance of the screw pump: check the appearance of the screw pump to ensure that all parts of the pump are intact, whether there are sealing problems, whether there are rust or corrosion, etc. At the same time, it is also necessary to check whether the connecting parts of the pump are fastened to ensure that the pump is firmly and reliably connected with the pipeline.

Check motor and electrical equipment: for screw pump with motor, check the working state of motor and corresponding electrical equipment. Check whether the wiring of the motor is correct and whether the motor has abnormal sound or odor. Ensure that the electrical equipment is in good condition and the power supply is normal.

Check the lubrication system: the manufacturer of ALLWEILER screw pump usually needs lubrication. Before use, it is necessary to check the oil supply of the lubricating system to ensure that the quality and quantity of lubricating oil are sufficient and whether the lubricating system works normally. For the lubrication system, it is also necessary to check whether the oil level and oil pressure of the lubricating oil are within the normal range.

Check the sealing system: The sealing system of ALLWEILER screw pump agent is very important to avoid medium leakage and gas entering the pump. Before use, it is necessary to check the working condition of the sealing system, ensure that the sealing elements are free from damage and aging, and replace them if necessary. In addition, it is also necessary to check the supply of sealing lubricant to ensure that the quality and quantity of lubricant are sufficient.

Check the cooling system: according to the working conditions of the screw pump and the temperature of the medium, check the working condition of the cooling system. If the screw pump needs to be cooled, check the supply of cooling water to ensure that the cooling system works normally.

Check the control valves and instruments: ALLWEILER screw pump is usually equipped with control valves and instruments to regulate the flow and monitor the working state of the pump. Before use, check whether the valve switch is flexible and reliable, and whether the reading of the instrument is accurate.

Commissioning: It is recommended to conduct commissioning before official use. The purpose of the test run is to verify the working state and performance of the screw pump and eliminate possible problems. During the test run, pay attention to whether the running direction of the pump is correct, whether the noise and vibration during operation are normal, and whether the temperature is too high.

Establish use records and maintenance plans: Before using ALLWEILER screw pump, it is recommended to establish use records and maintenance plans. The use record helps to find problems in time and record the working condition of the pump. The maintenance plan can guide the regular inspection and maintenance of the screw pump to extend its service life.

Through the above preparations, it can ensure that ALLWEILER screw pump meets the working requirements before formal use, and improve its working efficiency and reliability.