Operation method and process of screw pump

2023-02-24 10:47:20
second

    IMO screw pump It is a positive displacement pump with common structure, mainly composed of driving motor and reducer, coupling rod and connecting rod box, stator and rotor. When working, the rotor is driven by the motor, and makes planetary tumbling in the stator. The mutually matched rotor and the elastic bushing of the stator form several mutually disconnected sealing cavities. Due to the rolling of the rotor, the sealing cavity moves axially from the suction end to the discharge end, and the medium is continuously transmitted from the suction end to the discharge end in the cavity.

  IMO screw pump

Screw pump The application methods and processes are as follows:

1. When starting the pump for the first time or using the pump that has been sealed for a long time again, the input liquid shall be injected, and the pump shaft shall be rolled several times with the aid of auxiliary tools, so as not to damage the stator. The pump cannot be started without liquid, which will damage the stator.

2. Start the motor for a moment, check the rotation direction of the pump, and confirm that it is the same with the direction marked on the pump housing before starting the operation.

3. After starting the pump, investigate whether the readings of the pressure gauge and vacuum gauge meet the requirements, pay attention to the movement, static, vibration and other working conditions of the pump, and immediately park the car to check if any abnormality is found.

4. During the initial initiation process, the allowable initial leakage of the packing seal (especially PTFE) should be adjusted evenly within 15 minutes of the initial initiation process. About 1/8 turn each time, adjust to low leakage. If the temperature of stuffing box rises sharply and the leakage decreases sharply, loosen the nut immediately and repeat the above process. ALLWEILER ,

5. When the pump works normally, the flow is controlled by adjusting the speed.